First Ever Triple Level O-cell® Test

Loadtest has performed the first ever Triple-Level O-cell® test at the Amelia Earhart Memorial Bridge site on the Missouri River, USA.
Named in honor of the pioneering aviator, the Amelia Earhart Memorial Bridge, spanning the Missouri River near her birthplace in Atchison, KS, was built in 1938. Nearing the end of its service life, the steel cantilever truss structure is slated for replacement by the Kansas DOT (KDOT). In order to facilitate the design of a new bridge, and possibly eliminate the mid-river support column of the current bridge, KDOT called on LOADTEST to perform a first-ever Triple-Level O-cell test.

The primary purpose of the test program was to assess shear capacities of the three distinct underlying shale layers, to facilitate the design of the replacement bridge foundations. Given the high anticipated capacity of the 1525 mm diameter, 48.7 m deep test pile and the need to fully mobilize all sections of the test pile, a first-ever triple-level O cell test configuration was selected.

Bi-directional Load Test Arrangement
Three levels of 27 MN capacity O-cells were installed on a purpose-built carrying frame, along with the necessary instrumentation. The top and middle O-cells were positioned at the boundary between the upper, middle and lower shales. The bottom O-cell was positioned near the pile tip in order to gain information about the bearing capacity of the lower shale layer. In order to match the design assumptions regarding scour (always a possibility on the fast-moving, flood-prone Missouri River), the concrete was only poured up to the top of the shale, with a temporary casing through the overburden used to keep the shaft open until completion of the test.

Pile Test Results
The combined load reached during four stages of testing was 158 MN, the second-highest pile test load ever achieved in North America. The maximum displacement of any of the four pile sections was 10.7 mm.


Analysis
The resulting four load-movement curves, along with the estimated pile stiffness and other design parameters were supplied as inputs to a commercially-available geotechnical Finite-Element Analysis (FEA) program. A top-down load analysis was run in order to estimate the settlements due to an axial top-down load. Use of the FEA allowed the load-movement properties of the four pile sections, which were isolated and measured independently by the O-cell test, to be re-integrated to produce a single load-settlement curve. In addition to integrating the test data into a load-settlement prediction, a copy of the FEA input file can be made available to the client, allowing him to investigate other design scenarios and optimize the pile foundation design, using actual measured response as the model input.

Conclusions
As with many preliminary load testing projects, the aim of the testing program was to evaluate the shear and bearing characteristics of the foundation soil layers. The final design can be optimized as a result of the test.


Client: Kansas DOT

Foundation Contractors: Midwestern Foundations

LOADTEST Midwest Regional Manager: William G. Ryan

Click here for printer friendly PDF datasheet on the Triple Level O-cell testing in USA(75kBytes)

Project Profiles:

Upcoming Conferences:

News: